Skip to article
New Visionnv.AIM
⌕ Search

Compositional Model Settings

Compositional Model Settings, illustration 1Select image to enlarge

The settings are used when the "Tracking" PVT model type is selected in the calculation settings. Contains the following elements:

  • Equation of state type – Soave Redlich Kwong or Peng Robinson;
  • Use PR78 corrections flag;
  • Use Volume Shift corrections – No corrections applied, only SHIFT, SHIFT and SHIFTS;
  • standard conditions values;
  • Viscosity calculation method selection – Lorenz Bray Clark or Pedersen;
  • Separation calculation type – Standard separation or Separator Train.
← Area 4. Calculation settings and run panel