Skip to article
New Visionnv.AIM
⌕ Search

Locally stored Equipment Catalog

Data structures are identical to the global catalog

1.List of pipes with their properties

The second row is the column list.

The third and subsequent rows are the table.

Column list:

NAME - pipe name [required field]

OUTERDIAM - outer diameter, mm [by default 73]

INNERDIAM - inner diameter, mm [by default 62]

ROUGHNESS - roughness, mm [by default 1.524e-2]

MASS - Linear mass, kg/m [by default 5]

*/

PIPING

[NAME] [OUTERDIAM] [INNERDIAM] [ROUGHNESS] [MASS]

[Name] [outer diameter, mm] [inner diameter, mm] [roughness, mm] [Mass, kg/m]

'7-28' 7.0 5.75 0.0065 28.0

'6.5-28' 6.5 5.0 0.0065 28.0

/

2.Pump section data

The first row is the section name [required row]

Subsequent rows are in key-value format:

MANUFACTURER - Manufacturer (designation, string) [by default 'BORETS']

SERIES - Series (designation, string)  [by default '5']

NOMINALRATE - Nominal flow rate, m³/day [by default 72]

FREQUENCY - Nominal frequency, Hz [by default 60]

POLSTAGES - Number of polynomial stages [by default 1]

LOADFACTOR - Load factor, n/a [by default 0]

OUTERDIAM - Outer diameter, mm [by default 92]

SHAFTDIAM - Shaft diameter, mm [by default 17]

MINRATE - Minimum flow rate, m³/day [by default 48]

MAXRATE - Maximum flow rate, m³/day [by default 96]

BREAKRATE - Chart flow rate, m³/day [by default 163]

MASS - Mass, kg [by default 189]

LENGTH - Length, m [by default 5.212]

Polynomials:

HEADPOL - head polynomial (arbitrary number of values) [by default 2.44E+01 1.08E-02 -4.72E-05 1.59E-07 -2.79E-10 1.34E-13 0.00E+00]

POWERPOL - power polynomial (arbitrary number of values) [by default 9.98E-02 2.76E-04 -1.40E-07 -5.07E-10 1.00E-12 -4.79E-16 0.00E+00]

*/

ESCPHOUSING

'BORETS 5-ESPM5-60'

MANUFACTURER 'BORETS'

SERIES        '5'

NOMINALRATE   72.0

FREQUENCY     60

POLSTAGES     1

LOADFACTOR    0.0

OUTERDIAM     92.0

SHAFTDIAM     17.0

MINRATE       48.0

MAXRATE       96.0

BREAKRATE     163.0

MASS          189.0

LENGTH        5.212

HEADPOL 2.44E+01 1.08E-02 -4.72E-05 1.59E-07 -2.79E-10 1.34E-13 0.00E+00

POWERPOL 9.98E-02 2.76E-04        -1.40E-07 -5.07E-10 1.00E-12 -4.79E-16 0.00E+00

/

3.Actual points for calculating the head polynomial

The first row is the ESP section name [required row]

The second and subsequent rows:

[Rate, m³/day] [Head, m]

*/

ESCPHEADMATCHPOINTS

'BORETS 5-ESPM5-60'

32.0  366.0

95.0  305.0

318.0 256.0

556.0 232.0

/

4.Actual points for calculating the power polynomial

The first row is the ESP section name [required row]

The second and subsequent rows:

[Rate, m³/day] [Power, kW]

*/

ESCPPOWERMATCHPOINTS

'BORETS 5-ESPM5-60'

32.0  30.0  

95.0  28.0  

318.0 29.0  

/

5.ESP and PCP motor data

The first row is the motor name [required row]

Subsequent rows are in key-value format:

MANUFACTURER - Manufacturer (designation, string) [by default 'BORETS']

SERIES - Series (designation, string) [by default '103']

MAXTEMP - Maximum temperature, °C [by default 200.0]

MAXFREQUENCY - Maximum frequency, Hz [by default 70.0]

OUTERDIAM - Outer diameter, mm [by default 103.0]

SHAFTDIAM - Shaft diameter, mm [by default 12.0]

SHAFTPOWER - Maximum high strength shaft power, kW [by default 240.0]

POLEPAIRS - number of pole pairs [by default 1]

LENGTH - Length, m [by default 6.748]

Nominal operating parameters in key-value format:

SPEED - Speed, rpm (mechanical angular rotational speed) [by default 3000.0]

EFFICIENCY - Efficiency, % [by default 79.4]

POWERCOEF - Power factor, n/a [by default 79.4]

SLIPPAGE - Slippage, % (may be replaced with downhole motor type — induction or PMM) [by default 0]

POWER - Power, kW [by default 27.2]

VOLTAGE - Voltage, kV [by default 2.0]

AMPERAGE - Current, A [by default 14.0]

Polynomials:

AMPERAGEPOL - current polynomial (arbitrary number of values) [by default 0.458 0.1161]

EFFICIENCYPOL - efficiency polynomial (arbitrary number of values) [by default 0.08585 0.16291]

SPEEDPOL - speed polynomial (arbitrary number of values) [by default 3 000.00 -90.0]

*/

ESMOTOR

'EDB-103'

MANUFACTURER    'BORETS'

SERIES          '103'

MAXTEMP         200.0

MAXFREQUENCY    70.0

OUTERDIAM       103.0

SHAFTDIAM       12.0

SHAFTPOWER      240.0

POLEPAIRS       1

LENGTH          6.748

Nominal operating parameters

SPEED         3000.0

EFFICIENCY    79.4

POWERCOEF     0.835                  

SLIPPAGE      0                

POWER         27.2

VOLTAGE       2000.0

AMPERAGE      14.0

AMPERAGEPOL 0.458 0.1161

EFFICIENCYPOL 0.08585 0.16291

SPEEDPOL 3 000.00 -90.0

/

6.Separator data

The first row is the separator name [required row]

Subsequent rows are in key-value format:

MANUFACTURER - Manufacturer (designation, string) [by default]

POWER - Power consumption, kW [by default]

MAXSEPARATION - maximum separation coefficient, % [by default]

MINRATE - Minimum flow rate, m³/day [by default]

MAXRATE - Maximum flow rate (maximum throughput), m³/day [by default]

OUTERDIAM - Outer diameter, mm [by default]

SHAFTDIAM - Shaft diameter, mm [by default]

MASS - Mass, kg [by default]

LENGTH - Length, m [by default]

Polynomials:

RATEPOL - rate polynomial (arbitrary number of values) [by default]

*/

ESCPSEPARATOR -- Gas Separator or Bolt on intake

'SEP-120'

MANUFACTURER   'BORETS'

POWER          2.0

MAXSEPARATION  0.9

MINRATE        10

MAXRATE        300.0

OUTERDIAM      36.0

SHAFTDIAM      12.0

MASS           400.0

LENGTH         50.0

RATEPOL        1.0 2.0 4.0 5.0 6.0

/

7.List of cables with their properties

The second row is the column list.

The third and subsequent rows are the table.

Column list:

NAME - Cable name [required field]

MANUFACTURER - Manufacturer (designation, string) [by default]

TYPE - Cable type, FLAT||ROUND [by default]

SIZE - Size including insulation, mm [by default]

MAXVOLTAGE - Maximum voltage, kV [by default]

RESISTANCE - Resistance, Ohm/m [by default]

INDRESISTANCE - Inductive resistance, Ohm/m/Hz [by default]

TEMPCOEF - Temperature coefficient, °C/A² [by default]

COREDIAM - Core diameter (copper), mm [by default]

WIDTH - Width, mm [by default]

THICKNESS - Thickness, mm [by default]

MAXTEMP - Maximum temperature, °C [by default]

*/

ESCABLE

[NAME] [MANUFACTURER] [TYPE] [SIZE] [MAXVOLTAGE] [RESISTANCE] [INDRESISTANCE] [TEMPCOEF] [COREDIAM] [WIDTH] [THICKNESS] [MAXTEMP]

'SL212-PPOTB' 'BORETS' FLAT 6.0 5.0        0.0002 7.0E-7 0.038 2.8 49.4 18.6 200.0

/

8.List of extensions with their properties (they differ from cables only by having a connector)

The second row is the column list.

The third and subsequent rows are the table.

Column list:

NAME - Cable name [required field]

MANUFACTURER - Manufacturer (designation, string) [by default]

CONNECTOR - Motor connector, string [by default]

TYPE - Cable type, FLAT||ROUND [by default]

SIZE - Size including insulation, mm [by default]

MAXVOLTAGE - Maximum voltage, kV [by default]

RESISTANCE - Resistance, Ohm/m [by default]

INDRESISTANCE - Inductive resistance, Ohm/m/Hz [by default]

TEMPCOEF - Temperature coefficient, °C/A² [by default]

COREDIAM - Core diameter (copper), mm [by default]

WIDTH - Width, mm [by default]

THICKNESS - Thickness, mm [by default]

MAXTEMP - Maximum temperature, °C [by default]

*/

ESMLE

[NAME] [MANUFACTURER] [CONNECTOR] [TYPE] [SIZE] [MAXVOLTAGE] [RESISTANCE] [INDRESISTANCE] [TEMPCOEF] [COREDIAM] [WIDTH] [THICKNESS] [MAXTEMP]

'MLE, ESP flat B 319 KELB P' 'BORETS' '-' FLAT 6.0 5.0 0.0002 7.0E-7 0.038  2.8 49.4 18.6 200.0

/

9.List of SRP rods with their properties

The second row is the column list.

The third and subsequent rows are the table.

Column list:

NAME - Rod name [required field - identifier for adding rods to the well model]

DIAM - Diameter, mm [by default]

DENSITY - density, kg/m³

WEIGHT - Rod weight in air, N/kg

STRESS - Allowable stress, atm

TENSILE - Tensile strength, atm

YIELD - Yield strength, atm

ELASTICITY - Elasticity, atm

YOUNGSMODULUS - Young's modulus, atm

COUPLINGDIAM - Coupling diameter, mm

*/

RODS

[NAME] [DIAM] [DENSITY] [WEIGHT] [STRESS] [TENSILE] [YIELD] [ELASTICITY] [YOUNGSMODULUS] [COUPLINGDIAM]

'GOST_16' 16.0 2000.0 7.8 980 6120 4086 493570 493570 38.0

/

10.List of SRP pumping units

The second row is the column list.

The third and subsequent rows are the table.

Column list:

NAME - Pumping unit name [required field - identifier for adding rods to the well model]

MANUFACTURER - Manufacturer (designation, string) [by default]

UNBALANCE - Structural unbalance, H

RODCAPACITY - Polished rod load, H

TORQUEFACTOR - Torque factor, mm

DISTANCEA - Distance from walking beam support to polished rod line, mm

DISTANCEC - Walking beam length from tail bearing to center bearing, mm

DISTANCEI - Horizontal distance between walking beam support axis and gearbox output shaft axis, mm

DISTANCEP - Pitman length, mm

DISTANCEH - Distance between walking beam support and horizontal, mm

DISTANCEG - Distance between gearbox output shaft and horizontal, mm

CRANKRADIUS - Crank radius, mm

STROKELENGTH - Stroke lengths, mm

*/

SRPUMPINGUNITS

[NAME] [MANUFACTURER] [UNBALANCE] [RODCAPACITY] [TORQUEFACTOR] [DISTANCEA] [DISTANCEC] [DISTANCEI] [DISTANCEP] [DISTANCEH] [DISTANCEG] [CRANKRADIUS] [STROKELENGTH]

'M-640D-305-168' 'Lufkin' -21618.349 135670.71 1910.258 8483.6 6858 5145.024 4914.9 7496.302 2848.102 1614.424 4267.2

/

← Model format description